PVC insulated wires and cables with rated voltages up to and including 450/750V
Key words:
Category:
- Product
- Parameters
- Installation
-
- Commodity name: PVC insulated wires and cables with rated voltages up to and including 450/750V
- Commodity ID: cp4001
This product is manufactured according to the standard of GB/T9330-2008 "PVC insulated PVC sheathed control cable with rated voltage 450/750V and below".
1. Product standard
This product is produced in accordance with the standards of GB/T5023-2008 "Rated voltage 450/750V and PVC insulated cables", JB8734-1998 "Rated voltage 450/750V and PVC insulated cables, wires and cords". Users need to produce according to the International Electrotechnical Commission's recommended standards IEC, British standards, German standards and American standards.2. Scope of applicationThis product is suitable for power plants, fixed wiring and flexible connection electrical appliances with a rated voltage of 450/750V and below.3. Use characteristics3.1 The rated voltage U0/U is 450/750V, 300/500V and 300/300V.3.2 The maximum allowable long-term working temperature of the cable conductor is 90℃227IEC07 (BV-90)——90℃.227IEC08 (RV-90)——90℃.Other models-70℃.3.3 The ambient temperature during cable laying should not be lower than 0°C.3.4 Cable bending radius:D≤25mm——≥4 DD>25mm——≥6 DD —Outer diameter of cable产品结构图
Description: 1-Conductor 2-Insulation layer 3-Inner cladding layer 4-filler 5-copper wire braided shield layer 6-outer sheath
-
Type of cable
Model
Name
Standard
227IEC01(BV)
General purpose single-core hard conductor non-sheathed cable
GB/T5023-2008
227IEC02(RV)
General purpose single-core soft conductor non-sheathed cable
227IEC05(BV)
Single-core solid conductor non-sheathed cable with conductor temperature of 70℃ for internal wiring
227IEC06(RV)
Single core soft conductor non-sheathed cable with conductor temperature of 70℃ for internal wiring
227IEC07(BV-90)
Single-core solid conductor non-sheathed cable with conductor temperature of 90℃ for internal wiring
227IEC08(RV-90)
Single core soft conductor non-sheathed cable with conductor temperature of 70℃ for internal wiring
227IEC10 (BVV)
Lightweight PVC sheathed cable
227IEC42(RVB)
Flat type non-sheathed cord
227IEC52(RVV)
Lightweight PVC sheathed cord
227IEC53(RVV)
Ordinary PVC flexible cord
BV
Copper core PVC insulated wire
JB8734-1998
BLV
Aluminum core PVC insulated wire
BVR
Copper core PVC insulated flexible cable
BVV
Copper core PVC insulated PVC sheathed round cable
BLVV
Aluminum core PVC insulated PVC sheathed round cable
BVVB
Copper core PVC insulated PVC sheathed round cable
BLVVB
Aluminum core PVC insulated PVC sheathed flat cable
RVS
Copper core PVC insulated and twisted flexible cable for connection
RVVP
Copper core PVC insulated and shielded PVC sheathed flexible cable
Production range
Model
Rated voltage V
Number of cores
Nominal cross section of conductor mm2
Standard
227IEC01(BV)
450/750
1
1.5~400
GB/T5023-2008
227IEC02(RV)
450/750
1
1.5~240
227IEC05(BV)
300/500
1
0.5~1
227IEC06(RV)
300/500
1
0.5~1
227IEC07(BV-90)
300/500
1
0.5~2.5
227IEC08(RV-90)
300/500
1
0.5~2.5
227IEC10 (BVV)
300/500
2、3、4、5
1.5~35
227IEC42(RVB)
300/300
2
0.5~0.75
227IEC52(RVV)
300/300
2、3
0.5~0.75
227IEC53(RVV)
300/500
2~24
0.75~6
BV
300/500
1
0.75~1
JB8734-1998
BLV
450/750
1
2.5~630
BVR
450/750
1
2.5~240
BVV
300/500
1
0.75~10
BLVV
300/500
1
2.5~10
BVVB
300/500
2、3
0.75~10
BLVVB
300/500
2、3
2.5~10
RVS
300/300
2
0.5~0.75
RVVP
300/300
1~24
0.3~6
Core series: 4, 5, 6, 7, 10, 12, 14, 16, 19 and 24
Main technical parameters of the cable
Nominal cross-section of conductor (mm2)
Model
Rated voltage V
Conductor type
Insulation thickness (mm)
Average outer diameter upper limit (mm)
Approximate cable weight (kg/km)
70℃ minimum insulation resistance (MΩ/km)
1.5
227IEC01(BV)
450/750
1
0.7
3.3
20.5
0.011
227IEC02(RV)
5
0.7
3.5
21.0
0.010
1.5
227IEC01(BV)
2
0.7
3.4
21.5
0.010
227IEC02(RV)
-
-
-
-
-
2.5
227IEC01(BV)
1
0.8
3.9
32
0.010
227IEC02(RV)
5
0.8
4.2
33
0.009
2.5
227IEC01(BV)
2
0.8
4.2
47
0.009
227IEC02(RV)
-
-
-
-
-
4
227IEC01(BV)
1
0.8
4.4
48
0.0085
227IEC02(RV)
5
0.8
4.8
47
0.0070
4
227IEC01(BV)
2
0.8
4.8
50
0.0077
227IEC02(RV)
-
-
-
-
-
6
227IEC01(BV)
450/750
1
0.8
4.9
67
0.0070
227IEC02(RV)
5
0.8
6.3
67
0.0060
6
227IEC01(BV)
2
0.8
5.4
69
0.0065
227IEC02(RV)
-
-
-
-
-
10
227IEC01(BV)
1
1.0
6.8
124
0.0065
227IEC02(RV)
5
1.0
7.6
125
0.0056
16
227IEC01(BV)
1
1.0
8.0
175
0.0050
227IEC02(RV)
5
1.0
8.8
179
0.0046
25
227IEC01(BV)
1
1.2
9.8
268
0.0050
227IEC02(RV)
5
1.2
11.0
276
0.0044
35
227IEC01(BV)
1
1.2
11.0
360
0.0040
227IEC02(RV)
5
1.2
12.5
383
0.0038
50
227IEC01(BV)
1
1.4
13.0
504
0.0045
227IEC02(RV)
5
1.4
14.5
540
0.0037
70
227IEC01(BV)
450/750
1
1.4
15.0
714
0.0035
227IEC02(RV)
5
1.4
17.0
752
0.0032
95
227IEC01(BV)
1
1.6
17.0
980
0.0035
227IEC02(RV)
5
1.6
19.0
975
0.0032
120
227IEC01(BV)
1
1.6
19.0
1190
0.0032
227IEC02(RV)
5
1.6
21.0
1220
0.0029
150
227IEC01(BV)
1
1.8
21.0
1470
0.0032
227IEC02(RV)
5
1.8
23.5
1520
0.0029
185
227IEC01(BV)
1
2.0
23.5
1830
0.0032
227IEC02(RV)
5
2.0
26.0
1850
0.0029
240
227IEC01(BV)
1
2.2
26.5
2395
0.0032
227IEC02(RV)
5
2.2
29.5
2415
0.0028
300
227IEC01(BV)
1
2.4
29.5
3005
0.0030
227IEC02(RV)
5
-
-
-
-
400
227IEC01(BV)
1
2.6
33.5
3830
0.0028
227IEC02(RV)
5
-
-
-
-
Nominal cross-section of conductor (mm2)
model
Rated voltage V
Insulation thickness (mm)
Average outer diameter upper limit (mm)
Approximate cable weight (kg/km)
70℃ minimum insulation resistance (MΩ/km)
0.75
BV
450/750
0.6
2.6
12
0.014
BLV
-
-
-
-
BVR
-
-
-
-
1.0
BV
0.6
2.8
15
0.013
BLV
-
-
-
BVR
-
-
-
-
1.5
BLV
-
-
-
-
BVR
-
-
-
-
2.5
BLV
0.8
3.9
16
0.010
BVR
0.8
4.1
34
0.001
4
BLV
0.8
4.4
23
0.0085
BVR
0.8
4.8
50
0.009
6
BLV
0.8
5.0
30
0.0070
BVR
0.8
5.3
69
0.0084
10
BLV
1.0
6.7
54
0.0065
BVR
1.0
6.8
124
0.0072
16
BLV
1.0
7.8
75
0.0050
BVR
1.0
8.1
174
0.0062
25
BLV
1.2
9.7
112
0.0050
BVR
1.2
10.2
298
0.0058
35
BLV
1.2
10.9
145
0.0040
BVR
1.2
11.7
389
0.0052
50
BLV
1.4
12.8
203
0.0045
BVR
1.4
13.9
534
0.0051
70
BLV
1.4
14.6
291
0.0035
BVR
1.4
16.0
737
0.0045
95
BLV
1.6
17.1
398
0.0035
※BVR
1.6
18.1
998
-
120
BLV
1.6
18.8
473
0.0032
※BVR
1.6
19.8
1228
-
150
BLV
1.8
20.9
587
0.0032
※BVR
1.8
22.4
1438
-
185
BLV
2.0
23.3
731
0.0032
※BVR
2.0
25.0
1813
-
240
BLV
2.2
26.6
943
0.0032
※BVR
2.2
27.8
2450
-
300
BLV
2.4
29.6
1105
0.0030
BVR
-
-
-
-
400
BLV
2.6
33.2
1398
0.0028
BVR
-
-
-
-
※Can be supplied according to user needs
Nominal cross section of conductor (mm2)
model
Number of cores
Conductor type
Insulation thickness (mm)
Average outer diameter upper limit (mm)
Approximate cable weight (kg/km)
70℃ minimum insulation resistance (MΩ/km)
0.5
227IEC52(RVV)
300/300V2core
5
0.5
6.0
39
0.012
2core
5
0.5
3.6×6.0
30
0.012
3core
5
0.5
6.2
50
0.012
2275EC42(RVB)
300/300V2core
6
0.8
3.0×6.0
23
0.016
3core
-
-
-
-
-
RVS 300/300V
2core
-
0.8
6.0
24
0.016
0.75
227IEC52(RVV)
300/300V2core
5
0.5
6.4
47
0.010
2core
5
0.5
3.9×6.4
43
0.010
3core
5
0.5
6.8
60
0.010
2275EC42(RVB)
300/300V2core
6
0.8
3.2×6.4
29
0.014
3core
-
-
-
-
-
227IEC53(RVV)
300/500V2core
5
0.6
7.6
49
0.011
3core
5
0.6
8.0
61
0.011
4core
5
0.6
8.6
75
0.011
5core
5
0.6
9.6
94
0.011
RVS 300/300V
2core
-
0.8
6.2
30
0.014
1.0
227IEC53(RVV)
300/500V2core
5
0.6
8.0
56
0.010
3core
5
0.6
8.4
71
0.010
4core
5
0.6
9.4
92
0.010
5core
5
0.6
10.0
110
0.010
1.5
227IEC53(RVV)
300/500V2core
5
0.7
9.0
75
0.010
3core
5
0.7
9.8
99
0.010
4core
5
0.7
11.0
128
0.010
5core
5
0.7
12.0
158
0.010
2275EC10(BVV)
300/500V2core
1
0.7
10.0
85
0.011
2
0.7
10.5
89
0.010
3core
1
0.7
10.5
106
0.011
2
0.7
11.0
111
0.010
4core
1
0.7
11.5
130
0.011
2
0.7
12.0
137
0.010
5core
1
0.7
12.0
155
0.011
2
0.7
12.5
164
0.010
2.5
227IEC53(RVV)
300/500V2core
5
0.8
11.0
113
0.009
3core
5
0.8
12.0
150
0.009
4core
5
0.8
13.0
188
0.009
5core
5
0.8
14.0
232
0.009
2275EC10(BVV)
300/500V2core
1
0.8
11.5
117
0.010
2
0.8
12.0
125
0.009
3core
1
0.8
12.0
150
0.010
2
0.8
12.5
160
0.009
4core
1
0.8
13.0
186
0.010
2
0.8
13.5
200
0.009
5core
1
0.8
14.0
224
0.010
2
0.8
14.5
240
0.009
4
2275EC10(BVV)
300/500V2core
1
0.8
12.5
154
0.0085
2
0.8
13.0
162
0.0077
3core
1
0.8
13.0
200
0.0085
2
0.8
13.5
210
0.0077
4core
1
0.8
14.5
264
0.0085
2
0.8
15.0
280
0.0077
5core
1
0.8
16.0
340
0.0085
2
0.8
17.0
338
0.0070
Nominal cross-section of conductor (mm2)
model
Number of cores
Conductor type
Insulation thickness (mm)
Average outer diameter upper limit (mm)
Approximate cable weight (kg/km)
70℃ minimum insulation resistance (MΩ/km)
6
2275EC10(BVV)
300/500V2core
1
0.8
13.0
200
0.0070
2
0.8
14.0
210
0.0065
3core
1
0.8
14.5
279
0.0070
2
0.8
15.5
292
0.0065
4core
1
0.8
16.0
352
0.0070
2
0.8
17.0
372
0.0065
5core
1
0.8
17.5
428
0.0070
2
0.8
18.5
452
0.0065
10
2275EC10(BVV)
300/500V2core
1
1.0
16.5
343
0.0070
2
1.0
17.5
354
0.0065
3core
1
1.0
17.5
458
0.0070
2
1.0
19.0
470
0.0065
4core
1
1.0
19.0
590
0.0070
2
1.0
20.5
615
0.0065
5core
1
1.0
21.0
720
0.0070
2
1.0
22.0
750
0.0065
16
2275EC10(BVV)
300/500V2core
1
-
-
-
-
2
1.0
20.0
480
0.0052
3core
1
-
-
-
-
2
1.0
21.5
653
0.0052
4core
1
-
-
-
-
2
1.0
23.5
845
0.0052
5core
1
-
-
-
-
2
1.0
26.0
1050
0.0052
25
2275EC10(BVV)
300/500V2core
1
-
-
-
-
2
1.2
24.0
715
0.0050
3core
1
-
-
-
-
2
1.2
26.0
985
0.0050
4core
1
-
-
-
-
2
1.2
28.5
1300
0.0050
5core
1
-
-
-
-
2
1.2
31.5
1600
0.0050
35
2275EC10(BVV)
300/500V2core
1
-
-
-
-
2
1.2
27.5
955
0.0044
3core
1
-
-
-
-
2
1.2
29.0
1310
0.0044
4core
1
-
-
-
-
2
1.2
32.0
1720
0.0044
5core
1
-
-
-
-
2
1.2
35.0
2100
0.0044
Nominal cross section of conductor (mm2)
model
Number of cores
Shielding copper wire diameter
Insulation thickness (mm)
Average outer diameter upper limit (mm)
Approximate cable weight (kg/km)
70℃ minimum insulation resistance (MΩ/km)
0.5
RVVP
300/300V1core
0.10
0.5
3.8
23
0.012
2core
0.15
0.5
6.8
49
0.012
3core
0.15
0.5
7.1
59
0.012
※ 4core
0.15
0.5
8.2
73
0.012
※ 5core
0.15
0.5
8.7
87
0.012
※ 6core
0.15
0.5
9.3
99
0.012
※ 7core
0.15
0.5
9.3
104
0.012
0.75
RVVP
300/300V1core
0.10
0.5
4.1
27
0.010
2core
0.15
0.5
7.4
57
0.010
3core
0.15
0.5
7.8
70
0.010
※ 4core
0.15
0.5
8.7
91
0.010
※ 5core
0.15
0.5
9.4
104
0.010
※ 6core
0.15
0.5
10.0
121
0.010
※ 7core
0.15
0.5
10.0
128
0.010
1.0
RVVP
300/300V1core
0.10
0.6
4.9
36
0.010
2core
0.15
0.6
8.2
68
0.010
3core
0.15
0.6
9.1
91
0.010
※ 4core
0.15
0.6
9.7
114
0.010
※ 5core
0.20
0.6
11.1
151
0.010
1.5
RVVP
300/300V1core
0.10
0.6
5.2
44
0.009
2core
0.15
0.6
9.2
91
0.009
3core
0.20
0.6
10.0
114
0.009
※ 4core
0.20
0.6
11.1
147
0.009
※ 5core
0.20
0.6
11.9
184
0.009
2.5
RVVP
300/300V1core
0.15
0.7
6.0
56
0.008
※ 2core
0.15
0.7
10.9
144
0.008
※ 3core
0.20
0.7
11.9
189
0.008
※ 4core
0.20
0.7
12.8
231
0.008
※Can be supplied according to user needs
Cable current carrying capacity (A)
model
Nominal cross-section of conductor (mm2)
Long-term continuous load allowable current capacity (maximum temperature of conductor is 70℃, ambient temperature is 30℃)
Cu
Al
1芯
2芯
3芯
1芯
BV
BLV
BVR0.75
15
-
-
-
1.0
18
-
-
-
1.5
23
-
-
18
2.5
31
-
-
24
4
42
-
-
33
6
54
-
-
42
10
78
-
-
60
16
105
-
-
82
25
140
-
-
110
35
175
-
-
135
50
225
-
-
175
70
275
-
-
210
95
340
-
-
265
120
365
-
-
285
150
425
-
-
330
185
490
-
-
380
RV
RVV
RVB
RVS0.3
8
6
4
-
0.4
10
8
5
-
0.5
12
9
7
-
0.75
14
11
8
-
1.0
17
13
10
-
1.5
22
17
11
-
2.5
29
24
18
-
4
40
-
-
-
6
51
-
-
-
10
74
-
-
-
16
100
-
-
-
25
135
-
35
165
-
-
-
50
215
-
-
-
70
260
-
-
-
-
本产品按GB/T9330-2008《额定电压450/750V及以下聚氯乙烯绝缘聚氯乙烯护套控制电缆》标准制造。